INSTALLATION &
OPERATION MANUAL
Radiant Infrared Electric Heater
IR15S
WALL MOUNT FOR OUTDOOR USE ONLY
IP65 Rated for Wet Conditions
Heat Controller
Radiant Infrared Heater
Installation & Operation
INSTALLATION & OPERATION
c. The distance between each end and adjoining
walls or surfaces must be at least 5' (1.5m).
See Figure 1.
To provide additional protection against fire and
injury, the installation of a ground fault circuit
interrupter (GFI) is strongly recommended.
d. DO NOT mount the heater at any angle greater
than 45o up or down from the horizontal
position. See Figure 2.
WARNING: For outdoor installation only!
1. Remove the heater from the packaging, and
remove all packing materials including the anti-
vibration foam around the emitter/lamp. Check
the heater, power cord, and plug for any signs of
damage. Do not install if damage is apparent.
e. The maximum swing rotation from side to side
(right to left/left to right) is 90o.
4. Check to be sure the installation of the heater does
not add excessive wind load.
2. Check the mounting materials (dowels and screws)
to ensure that they are suitable to ensure a stable
and secure mounting of the heater.
5. Attach the mounting bracket to the wall, making
sure that it is secure to support the weight of the
heater. Keep in mind that mechanical bearing
pressure and oscillation due to wind or rain could
lead to loosening.
3. Select a location for mounting following these
guidelines:
WARNING
6. Plug the power cord into the electrical outlet.
SAFETY HAZARDS
7. Turn the unit on. The heater has a red ON/OFF
switch located on the side of the unit.
The minimum safe mounting clearances and tilt
angles must be strictly followed. See below and
Figures 1 and 2.
8. Observe the operation for 10 to 15 minutes to be
sure the unit is working properly.
a. The distance between the bottom edge of
the heater and the floor must be at least 6' 7"
(2.0m). See Figure 1.
If there is an operation problem, immediately turn
OFF the heater and disconnect the power cord
from the electric outlet.
b. The distance between the top of the heater and
the ceiling/roof/overhead material must be at
least 1' 6" (0.5m). See Figure 1.
9. Do not leave the heater unattended while
operating. Turn the unit OFF when use is not
desired.
Min. 1' 6" (0.5m)
Min. 5' (1.5m)
Min. 6' 7" (2.0m)
POWER:
1.5 kW, 120V-1-60
3
Installation & Operation
Radiant Infrared Heater
Heat Controller
MAINTENANCE
1. Your heater is a robust unit with an aluminum
casing and protective cover, and requires
only minimal maintenance. There are no user
serviceable parts inside.
4. Never use abrasive cleaners, scrubbing brushes or
chemical cleaners on the heater, column or base.
Alcohol can be used to clean the unit exterior.
WARNING
PERSONAL INJURY HAZARD
2. Before cleaning, turn the unit OFF and remove the
plug from the power outlet. Wait until the heater
has cooled down.
5. To protect against electric shock and danger of
death, do not immerse cord, plug, or any part of the
heater in water or other liquid.
3. Wipe with a clean lint-free cloth or a soft brush.
SERVICE
1. Repairs must be carried out by service specialists
to ensure electrical safety. Contact an authorized
servicer or qualified electrician for service.
WARNING
PERSONAL INJURY HAZARD
2. Improper repairs could result in death or personal
injury to users. USERS SHOULD NOT ATTEMPT
TO MAKE REPAIRS.
4
Limited Express Warranty
Comfort-Aire® Infrared Heaters
RESIDENTIAL INSTALLATION/USE:
consumer must retain a receipted bill of sale as proof of warranty
period. Without this proof, the express warranty begins on the
date of shipment from the factory.
LIMITED ONE (1) YEAR PARTS EXPRESS WARRANTY
Heat Controller warrants all parts of the Infrared Heaters to
be free from defects in workmanship and materials for normal
residential use and maintenance for one (1) year from the date
of purchase by the original consumer.
REMEDYPROVIDED BYTHE LIMITED EXPRESS WARRANTY
The sole remedy under the Limited Warranty is replacement of
the defective part. If replacement parts are required within the
period of this warranty, Heat Controller replacement parts shall
be used; any warranty on the replacement part(s) shall not affect
the applicable original unit warranty. Labor to diagnose and
replace the defective part is not covered by this Limited Express
Warranty. If for any reason the replacement part/product is no
longer available during the warranty period, Heat Controller
shall have the right to allow a credit in the amount of the current
suggested retail price of the part/product instead of providing
repair or replacement.
LIMITED THREE (3) YEAR EXPRESS WARRANTY ON BULB
Heat Controller warrants the heater bulb to be free from defects
in workmanship and materials for normal residential use and
maintenance for three (3) years from the date of purchase by
the original consumer.
COMMERCIAL INSTALLATION/USE:
LIMITED ONE (1) YEAR PARTS EXPRESS WARRANTY
Heat Controller warrants all parts of the Infrared Heaters to
be free from defects in workmanship and materials for normal
commercial use and maintenance for one (1) year from the date
of purchase by the original consumer.
LIMITATION OF LIABILITY
The Express Limited Warranties described above apply only
when the Infrared Heater is installed and operated per Heat
Controller installation and operating instructions for normal use.
1. There are no other express or implied warranties. Heat
Controller makes no warranty of merchantability. We do not
warrant that the unit is suitable for any particular purpose or
can be used in buildings or rooms of any particular size or
condition except as specifically provided in this Installation
and Operation document. There are no other warranties,
express or implied, which extend beyond the description in
this document.
EXCEPTIONS
The Limited Express Warranty does not cover normal
maintenance—Heat Controller recommends that regular
inspection/maintenance be performed according to the
Installation and Operation Manual. Additionally, labor charges,
diagnostic charges, transportation charges for replacement parts,
or any other service calls/repairs are not covered by this Limited
Warranty. It also does not cover any portion or component of the
system that is not supplied by Heat Controller, regardless of the
cause of failure of such portion or component.
2. All warranties implied by law are limited in duration to the
one-year term of the Parts Warranty. Your exclusive remedy
is limited to the replacement of defective parts. We will not
be liable for any consequentialorincidentaldamagescaused
by any defect in this unit.
3. This warranty gives you specific legal rights and you may
also have other rights which vary from state to state. Some
states do not allow limitation on how long an implied warranty
lasts or do not allow the exclusion or limitation of incidental or
consequential damages, so the above limitations or exclusions
may not apply to you.
CONDITIONS FOR WARRANTY COVERAGE
• Unit must be operated according to Heat Controller operating
instructions included with the unit and cannot have been
subjected to accident, alteration, improper repair, neglect or
misuse, or an act of God (such as a flood)
• Installation must be according to Heat Controller installation
instructions
4. No warranties are made for units sold outside the continental
United States and Canada. Your distributor or final seller may
provide a warranty on units sold outside these areas.
• Rating plate has not been altered or removed
• Unit is not operated in a corrosive environment
5. Heat Controller will not be liable for damages if our performance
regarding warranty resolution is delayed by events beyond our
control including accident, alteration, abuse, war, government
restrictions, strikes, fire, flood, or other acts of God.
• Performance cannot be impaired by use of any product not
authorized by Heat Controller, or by any adjustments or
adaptations to components
• Damage has not been a result of inadequate wiring or
voltage conditions, use during brown-out conditions, or circuit
interruptions
HOW TO OBTAIN WARRANTY SERVICE OR PARTS
If you have a warranty claim or service question, contact Heat
Controller at 517-787-2100. Have the model number and date
of purchase available for this call. Do not return your unit to the
store where it was purchased.
• Unit was not purchased over the internet.
DURATION OF WARRANTY & REGISTRATION
The warranty begins on the date of purchase by the orginal
consumer. The consumer must register the product purchase
Owner responsibilities are set forth in the
instruction manual—read it carefully.
5
This page intentionally left blank.
6
This page intentionally left blank.
7
Design, material, performance specifications and components
subject to change without notice.
ꢀꢁꢂꢂꢃ:HOOZRUWKꢃ$YHꢄꢅꢃ-DFNVRQꢃ0,ꢃꢆꢁꢇꢂꢈꢃꢃꢃꢃ3KꢄꢃꢉꢀꢊꢋꢊꢌꢊꢋꢇꢀꢂꢂꢃꢃꢃꢃZZZꢄKHDWFRQWUROOHUꢄFRP
ꢃ
ꢃꢃ
07/2013
|