Hearth and Home Technologies Electric Heater SL 350TRSI AUE User Manual

INSTALLATION AND OPERATION  
INSTRUCTIONS  
Í
MODEL: SL-350TRSI-AUE  
AUSTRALIAN GAS ASSOCIATION APPROVED  
Approval Number 5666  
THIS MANUAL MUST BE USED FOR INSTALLATION AND RETAINED  
BY HOMEOWNER FOR OPERATION AND MAINTENANCE.  
HEAT & GLO, a brand of Hearth & Home Technologies Inc.  
20802 Kensington Boulevard, Lakeville, MN 55044 USA  
THIS PRODUCT MAY BE COVERED BY ONE OR MORE OF THE FOLLOWING PATENTS:  
(United States) 4593510, 4686807, 4766876, 4793322, 4811534, 5000162, 5016609, 5076254, 5113843, 5191877, 5218953, 5263471, 5328356, 5341794, 5347983, 5429495, 5452708, 5542407,  
5601073, 5613487, 5647340, 5688568, 5762062, 5775408, 5890485, 5931661, 5941237, 5947112, 5996575, 6006743, 6019099, 6048195, 6053165, 6145502, 6170481, 6237588, 6296474,  
6374822, 6413079, 6439226, 6484712, 6543698, 6550687, 6601579, 6672860, 6688302B2, 6715724B2, 6729551, 6736133, 6748940, 6748942, D320652, D445174, D462436; (Canada) 1297749,  
2195264, 2225408; (Australia) 543790;586383; (Mexico) 97-0457; (New Zealand) 200265;or other U.S. and foreign patents pending.  
Heat & Glo • SL-350TRSI-AUE • 2089-902 Rev. B • 6/06  
1
 
TABLE OF CONTENTS  
1.0 Installation Instructions......................................................................................... 5  
1.1 Introduction ................................................................................................... 6  
Í
1.2 Flue SystemApprovals and Installation ......................................................... 8  
1.3 Connecting the Gas Supply ........................................................................ 22  
1.4 Ignition System Wiring ................................................................................ 23  
1.5 Blower Fan................................................................................................. 24  
1.6 Finishing .................................................................................................... 25  
1.7 Installer Testing ........................................................................................... 26  
Í
1.8 Log Placement ........................................................................................... 27  
2.0 Operating Instructions ....................................................................................... 30  
2.1 Safety and Lighting Information................................................................... 31  
2.2 Fan Operation ............................................................................................ 32  
3.0 Servicing and Maintenance............................................................................... 32  
3.1 Removal of Covers for Servicing ................................................................ 33  
3.2 Removal of Components for Service .......................................................... 33  
3.3 Parts Replacement..................................................................................... 33  
3.4 Adjustments and Replacement Parts .......................................................... 33  
3.5 Troubleshooting .......................................................................................... 34  
Í
4.0 Replacement Parts ........................................................................................... 35  
Limited Warranty............................................................................................... 37  
Heat & Glo • SL-350TRSI-AUE • 2089-902 Rev. B • 6/06  
3
 
22-3/4 in.  
(577mm)  
11-3/8 in.  
(289mm)  
16-3/8 in.  
(414mm)  
15-7/8 in.  
(402 mm)  
8-3/4 in.  
(223mm)  
Ø6-5/8 in.  
(167mm)  
Ø8 in.  
(203mm)  
ELECTRICAL  
ACCESS  
24 in.  
(610mm)  
GAS LINE  
ACCESS  
41-3/4 in.  
(1060mm)  
30 in.  
(764mm)  
15-1/8 in.  
(384mm)  
3-1/2 in.  
(90mm)  
21-3/8 in.  
(542mm)  
30-5/8 in.  
(777mm)  
2-1/8 in.  
(55mm)  
28-1/8 in.  
(714mm)  
5-5/8 in.  
(144mm)  
6-7/8 in.  
(175mm)  
33 in.  
(837mm)  
TOP STANDOFFS  
FLUE COLLAR  
COVER PLATE  
HOOD  
RATING PLATE/LABELS  
( BEHIND DOOR)  
BOTTOM  
ACCESS DOOR  
GAS  
CONTROLS  
( BEHIND DOOR)  
ELECTRICAL  
ACCESS  
GAS  
ACCESS  
Í
Figure 1. Diagram of SL-350TRSI-AUE  
Heat & Glo • SL-350TRSI-AUE • 2089-902 Rev. B • 6/06  
4
 
Clearance Requirements  
The top and back of fireplace are defined by stand-offs.  
Top Flue  
1in. Min. (25mm)  
The heat shield must be attached as shown if combus-  
tible materials are placed directly on top standoffs (Fig-  
ure 3).  
B
The minimum clearance to a perpendicular wall ex-  
tending past the face of the fireplace is 25mm.  
A
The back of the fireplaces may be recessed into com-  
bustible construction, as shown above.  
TOP  
STANDOFFS  
E
D
INSTALLED  
HEAT SHIELD  
C
½ in. Min (13mm)  
A
B
C
D
E
Millimeter  
837  
413  
728  
1001  
1416  
Rear Flue  
HEAT SHIELD  
1 in. MIN. (25mm)  
B
Figure 3. Heat Shield  
A
1.0 INSTALLATION INSTRUCTIONS  
NOTE: Not intended for fireplace insert.  
In planning the installation for the heater it is necessary  
to determine where the unit is to be installed, the type  
of flue system to be used (straight out, corner, or el-  
evated), and whether optional accessories (wall switch  
or remote control) are desired. Gas supply piping should  
also be planned. Refer to the appliance data plate on  
the base pan of the heater for all gas pressures and  
input rate information.  
E
D
C
The heater can be mounted on any of the following sur-  
face:  
1 in. MIN. (25mm)  
A
B
413  
C
D
E
1. A flat surface (minimum 6mm base).  
2. Four (4) corner supports.  
Millimeter  
837  
843  
1192  
1686  
(Example: Four (4) concrete masonry blocks). These  
supports must be positioned so they contact all four (4)  
perimeter edges on the bottom of the unit.  
Figure 2. Fireplace Dimensions, Locations, and  
Space Requirements  
Heater framing can be built before or after the heater is  
set in place. Framing should be positioned to accom-  
modate wall covering and heater facing material. The  
heater framing should be constructed of 2" X 4" (51 x  
102mm) lumber or heavier. The framing headers may  
rest on the heater standoffs. Refer to Figure 2 and Fig-  
ure 4 for heater and framing reference dimensions.  
Heat & Glo • SL-350TRSI-AUE • 2089-902 Rev. B • 6/06  
 
5